Solar Calculator Canada

Solar Power Calculator for Tee Lake, Quebec, Canada

Solar Output Report

The reports were generated based on 100 kWp solar system as it is easier to calculate any other size based on the results.

Location:
  • Location: Tee Lake
  • GPS Coordinates: 46.755833, -79.044444
  • Elevation: 258 m
Solar Installation Info:
  • Total installed power: 100 kWp
  • Solar panel technology: c-Si
  • Installation: Fixed
  • Optimal solar panel angle for Tee Lake: 39o
  • Average yearly irradiance: 1505.69 kWh/m2
  • Average yearly power output: 127530 kWh
Sun Path Tee Lake

Average yearly irradiance delivered by the Sun in Tee Lake is 1505.69/kWh/m2 at the optimal panel slope of 39o. After taking all losses into account, you can expect about 127530 kWh for every 100 kWp installed solar panels.

Solar irradiance and output report at optimal angle - 39o

Solar irradiance

Month Average Daily kWh/m2/d Average Monthly kWh/m2/mo
January 2.61 80.87
February 3.69 103.21
March 4.88 151.41
April 5.03 150.88
May 5.52 171.25
June 5.41 162.3
July 5.57 172.74
August 5.22 161.79
September 4.38 131.43
October 3.17 98.38
November 2.23 66.75
December 1.76 54.66
Total yearly 1505.69

Solar power output

Month Average Daily kWh/d Average Monthly kWh/mo
January 248.89 7715.73
February 347.38 9726.7
March 440.55 13657.2
April 429.95 12898.6
May 452.89 14039.6
June 432.83 12984.9
July 441.56 13688.3
August 416.86 12922.6
September 357.3 10718.9
October 268.46 8322.3
November 194.8 5843.89
December 161.65 5011.26
Total yearly 127530

Solar power output reports at other common angles

As it is not always possible to install the solar panels at the optimum angle, we calculated some more options so you can get a better idea of the difference. A 3/12 roof pitch corresponds to about 14o slope so the result should be just a bit below the 15o output. 4/12 roof pitch(18.4o) falls between 15o and 20o. 5/12 pitch is 22.6o, 6/12 is 26.6o, 7/12 is 30.3o etc...

Tee Lake solar output calculated at 15o

Month Average Daily kWh/d Average Monthly kWh/mo
January 176 5456.07
February 272.22 7622.03
March 385.66 11955.6
April 420.54 12616.1
May 475.63 14744.5
June 469.96 14098.8
July 472.47 14646.7
August 420.44 13033.8
September 329.25 9877.51
October 224.6 6962.56
November 145.94 4378.18
December 113.41 3515.67
Total yearly 118907

Solar power generation calculated at 20o

Month Average Daily kWh/d Average Monthly kWh/mo
January 194.38 6025.64
February 291.92 8173.67
March 401.96 12460.8
April 427 12809.8
May 475.57 14742.7
June 466.08 13982.3
July 470.06 14571.9
August 424.05 13145.6
September 338.94 10168.2
October 236.7 7337.67
November 158.42 4752.56
December 125.5 3890.41
Total yearly 122061

Solar power output calculated at 25o

Month Average Daily kWh/d Average Monthly kWh/mo
January 211.02 6541.7
February 309.47 8665.05
March 415.7 12886.7
April 431.12 12933.6
May 472.97 14662.2
June 460.73 13821.9
July 466.06 14448
August 425.37 13186.4
September 346.62 10398.6
October 247.23 7664.14
November 169.67 5090.11
December 136.49 4231.09
Total yearly 124529

Tee Lake Solar generation calculated at 30o

Month Average Daily kWh/d Average Monthly kWh/mo
January 225.91 7003.28
February 324.82 9094.89
March 426.84 13232.1
April 432.9 12987
May 467.99 14507.7
June 452.79 13583.8
July 459.45 14243.1
August 424.61 13163
September 352.27 10568
October 256.16 7940.97
November 179.65 5389.62
December 146.34 4536.69
Total yearly 126250

Looking for a different report? Feel free to drop us a line and we will get back to you ASAP.

Solar panels on a pole

Solar power calculation notes:

We made a few assumptions when making the above solar power output calculations.

Losses: The numbers in the reports take into account 10% technological losses based on the electrical parts of a solar installation. There are also -2.85% angle of incidence loss and -3.13% temperature and irradiance loss. This totals to about -15.3%.

Location: We do not know your exact location so we can not take into account your surroundings, the elevation and terrain specifics. The solar power output calculations are based on panels being optimally facing the sun in the optimal case or uniformly faced South in the other cases.

Errors: Please keep in mind that although we did our best, the information presented here might contain errors. As such, please contact a local solar installer for individual report based on your exact location.

Solar panel degradation: Solar panels lose efficiency over time. The reports are valid for the initial panel installation. Most solar panel manufacturers guarantee 80% generation after 25 years.

More locations: